Indicative only. This tool encodes the demarcation values printed on the Annex II tables and the Article 4(1) scope thresholds. It is a fast first answer, not a conformity assessment: confirm any real equipment against the tables in Directive 2014/68/EU and against the applicable harmonised standard before you commit a route.

—

Annex II table
—
Category
—
Conformity assessment modules
—
Governing value
—
    Check before you rely on it. Borderline cases, assemblies, multi-chamber vessels and equipment containing more than one fluid are not covered here — each chamber is classified separately and the highest category governs (Article 13(2)).

    Which Annex II table applies

    The table is chosen from three things only: the type of equipment, whether the contents are treated as a gas or a liquid, and the fluid group. A fluid counts as a gas when its vapour pressure at the maximum allowable temperature is more than 0.5 bar above atmospheric — water at a TS of 120 °C is therefore assessed as a gas.

    EquipmentFluid groupGas / vapourLiquid
    VesselGroup 1Table 1Table 3
    VesselGroup 2Table 2Table 4
    Fired or heated, steam / superheated water > 110 °CAnyTable 5Table 5
    PipingGroup 1Table 6Table 8
    PipingGroup 2Table 7Table 9
    Safety accessoryAnyCategory IVCategory IV
    Pressure accessoryAnyVessel or piping table, own PS and sizeVessel or piping table, own PS and size

    Article 4(1): when the directive applies at all

    Below these thresholds the equipment is designed to sound engineering practice (SEP, Article 4(3)) and does not carry a PED CE marking. Above them, the equipment falls into a category and the corresponding table decides how far up it sits.

    TableEquipment and fluidIn scope when
    1Vessel, group 1 gasV > 1 L and PS·V > 25 bar·L, or PS > 200 bar
    2Vessel, group 2 gasV > 1 L and PS·V > 50 bar·L, or PS > 1000 bar
    3Vessel, group 1 liquidV > 1 L and PS·V > 200 bar·L, or PS > 500 bar
    4Vessel, group 2 liquidPS > 10 bar and PS·V > 10 000 bar·L, or PS > 1000 bar
    5Fired or heated steam generatorV > 2 L
    6Piping, group 1 gasDN > 25
    7Piping, group 2 gasDN > 32 and PS·DN > 1000 bar·mm
    8Piping, group 1 liquidDN > 25 and PS·DN > 2000 bar·mm
    9Piping, group 2 liquidPS > 10 bar, DN > 200 and PS·DN > 5000 bar·mm

    The category bands, table by table

    The demarcation lines printed on each Annex II table, written out as values. Each line marks the upper limit of a category, so a value that sits on a line belongs to the category below it.

    TableDiagonals / caps on the tableCategory
    1PS·V 25 / 50 / 200 / 1000; PS 200; PS 1000 I: PS·V ≤ 50 · II: ≤ 200 · III: ≤ 1000 · IV: > 1000. At V ≤ 1 L: III above 200 bar, IV above 1000 bar
    2PS·V 50 / 200 / 1000 / 3000; PS 1000; PS 3000 I: ≤ 200 · II: ≤ 1000 · III: ≤ 3000 · IV: > 3000. At V ≤ 1 L: III above 1000 bar, IV above 3000 bar
    3PS·V 200; PS 10; PS 500 I: above the 200 line up to PS 10 bar · II: PS 10–500 bar · III: above 500 bar, except V ≤ 1 L above 500 bar which is II
    4PS·V 10 000; PS 1000 / 500 / 10; V 10 / 1000 I: above 1000 bar at V ≤ 10 L, and above the 10 000 line between PS 10 and 500 bar · II: above 500 bar at V > 10 L · below the staircase: out of scope. No category III or IV
    5PS·V 50 / 200 / 3000; PS 32; V 1000 I: ≤ 50 · II: ≤ 200 · III: ≤ 3000 · IV: > 3000 or V > 1000 L
    6PS·DN 1000 / 3500; DN 25 / 100 / 350 DN 25–100: I to 1000, II above · DN 100–350: II to 3500, III above · DN > 350: III
    7PS·DN 1000 / 3500 / 5000; DN 32 / 100 / 250 I: to 3500 · II: to 5000 · III: above 5000 or DN > 250
    8PS·DN 2000; PS 10; PS 500; DN 25 I: above the 2000 line up to PS 10 bar · II: PS 10–500 bar · III: above 500 bar
    9PS·DN 5000; PS 10; PS 500; DN 200 I: above the 5000 line up to PS 500 bar · II: above 500 bar

    Categories and their conformity assessment modules

    CategoryModules (Annex II, point 1)Notified body
    IModule A — internal production controlNo
    IIModules A2, D1 or E1Yes
    IIIB (design type) + D, B (design type) + F, B (production type) + E, B (production type) + C2, or HYes
    IVB (production type) + D, B (production type) + F, G, or H1Yes

    A manufacturer may always choose a procedure from a higher category than the minimum one (Article 14(3)). From category II upward a notified body is involved and its number appears beside the CE marking.

    Exceptions that move equipment up a category

    • Unstable gas (Tables 1 and 6): a vessel or piping that would land in category I or II is classified in category III.
    • Portable extinguishers and breathing-apparatus bottles (Table 2): classified at least in category III.
    • Pressure cookers (Table 5): the design is subject to a conformity assessment procedure equivalent to at least one of the category III modules.
    • Piping above 350 °C (Table 7): piping that would land in category II is classified in category III.
    • Safety accessories: category IV by default, but a safety accessory made for specific equipment may take the category of the equipment it protects.
    • Pressure accessories: classified on their own PS, V or DN and fluid group using the vessel or piping table; where both V and DN are appropriate, the highest category applies.
    • Multi-chamber vessels: each chamber is classified separately and the vessel takes the highest category (Article 13(2)).

    What this calculator does not do

    It does not decide the fluid group for you — whether a fluid is group 1 depends on its classification as dangerous, including the flashpoint rule for a liquid above its flashpoint at the maximum allowable temperature. It does not cover assemblies, nor equipment excluded by Article 1(2) because another directive governs it. And it reads the tables, not your design: PS is the maximum allowable pressure set by the manufacturer, not the operating pressure, and V is the internal volume of the chamber including nozzles up to the first connection.

    Not sure which route your equipment takes?

    Category selection is the cheap part of a PED project; the design route and the technical file are where projects lose time. Tell us the equipment and we will respond within one business day.

    Get in Touch PED Compliance