Compare predicted values with measured values, quantity by quantity

FEA test correlation is the comparison itself: the predicted value and the measured value for the same quantity, at the same location, under the same load. This checker takes those pairs and reports the difference for each one. It deliberately does not reduce the comparison to a single number, because a single number cannot tell you which quantity the model gets wrong.

Your own tolerance, set by you for this comparison. It is not a requirement taken from any standard.

Percentage is taken of

The choice changes the numbers because the denominator changes: a predicted 105 against a measured 100 is +5.00% of the measured value but only +4.76% of the predicted one. Pick one convention and use it for every row, and say in the report which you used.

Predicted and measured values. A positive difference means the simulation predicted more than the test measured.
Load case / label Quantity Predicted Measured Unit Remove

Results

With JavaScript off, the comparison cannot be computed in the browser. The worked example below gives the same calculation for the five quantities above, done by hand, so the method is still readable.

What this checker computes. For each row: the absolute difference (predicted − measured), the percentage difference in the convention you chose, the ratio predicted ÷ measured, and an in-band or out-of-band flag against your tolerance. The summary reports how many rows are in band, the worst row by absolute percentage, the mean absolute percentage error over the rows that could be computed, and the largest absolute deviation. Nothing is sent anywhere — the arithmetic runs in your browser.

How to use this checker

  • Enter one row per quantity, not one row per test. A stiffness, a stress at a named location, a natural frequency and a strain at a gauge are four quantities and four rows.
  • Put the load case in the label column so the comparison stays traceable: the same quantity at a different load is a different row.
  • Type the numbers as they are: both negative and positive values are accepted, and scientific notation such as 1.2e-3 is fine.
  • Set the tolerance band to the value you are prepared to defend, then state that number in the correlation report. The band is a decision you make, not something the tool imposes.
  • Choose the percentage convention once and keep it. If you switch it later, the percentages change even though nothing about the model or the test has changed.
  • Read the summary last. The per-row flags are what tell you where the model disagrees with the test; the mean absolute percentage error is only a headline.
  • A row reported as not computable means the arithmetic is undefined for it — a measured value of zero, or a missing entry. It is not treated as zero error and it is not counted as in band.

The correlation procedure, as a checklist

The seven steps below are the order that makes a comparison defensible. Work through them before you trust any number this checker produces, because a correctly calculated percentage on mismatched data is still meaningless.

  • Step 1 — Name the quantities. Write down which outputs you are comparing before you compare them. A model is checked for the quantities you list and for nothing else; each one is governed by different inputs, so a good stiffness match says nothing about fatigue life.
  • Step 2 — Instrument where the model predicts the extreme. Put gauges and transducers where the simulation says the peak is, not where they are easy to fit. A gauge at a nominal location tells you nothing about whether the model can predict the peak.
  • Step 3 — Match the boundary conditions and record the mismatch. A test article bolted to a rig is not a fixed face in a model. Write down the real support stiffness, the bolt preload and the fixture compliance, then check whether that difference explains the gap before you touch the material data.
  • Step 4 — Measure the load, not just the response. Applied load, pressure, temperature and strain belong on one time base. A load case you did not record properly invalidates the comparison however careful the model is.
  • Step 5 — Compare like with like. Measured strain against predicted strain at the same point, same direction, same load step. A local measured peak against a modelled element average, or a surface value against a mid-surface value, produces a difference that belongs to the comparison rather than to the model.
  • Step 6 — Quantify the error per quantity, and find where it is worst. That is what this checker does. Report the percentages row by row and name the region of largest deviation; a single global figure hides exactly the information you need.
  • Step 7 — State the validity envelope. Record the loads, temperatures, materials and failure modes for which the model has now been checked. Outside that envelope the model is a hypothesis again.

What a correlation result does and does not establish

A comparison like the one above is evidence about the model in a specific, narrow sense. Being clear about that narrowness is what makes the result usable.

What it does establish. That for the quantities you compared, over the load and temperature range you actually tested, for that material and that geometry, the model reproduces the measured behaviour to within the tolerance you set. That is a real and useful statement — it is the statement that lets you extrapolate with a quantified margin instead of a hope.

What it does not establish. It is not proof that the model is right. Agreement inside a band can come from a model whose errors happen to cancel at the point you measured: a mesh that is too stiff combined with a modulus that is too low can produce a deflection that matches while the stress field underneath is wrong. It says nothing about a quantity you did not compare, a load level you did not apply, a temperature you did not reach, a material heat you did not test, or a failure mode your model does not represent at all.

A single global error figure is worse than the per-row table, not better, because it averages away the information that matters: a model that is 2% out on four quantities and 40% out on the fifth can report a comfortable mean while being unusable for the fifth. The row-by-row flags are the point of the exercise.

None of this is new physics — it is the same distinction between verification and validation that ASME V&V 10 draws: solving the equations correctly is not the same as having put the right physics and the right inputs in. Correlation addresses the second question only, and only over the range you tested.

Worked example

Five quantities from one instrumented test, compared with the model. The tolerance band is ±10% and the convention is percentage of the measured value. These are the rows the checker above is loaded with, and the figures below are the arithmetic by hand.

Worked example — predicted vs measured at a ±10% tolerance, percentage of the measured value
Label Quantity Predicted Measured Difference Difference % Ratio Status
LC1 weld toe Peak von Mises stress (MPa) 248 262 -14 -5.34% 0.9466 In band
Modal First natural frequency (Hz) 42.5 44.0 -1.5 -3.41% 0.9659 In band
LC1 midspan Vertical deflection (mm) 6.8 5.9 0.9 +15.25% 1.1525 Out of band
LC2 bolted joint Bolt axial load (kN) 18.2 17.5 0.7 +4.00% 1.04 In band
LC1 gauge 7 Surface strain (µε) 1140 1240 -100 -8.06% 0.9194 In band

The arithmetic for the worst row is (6.8 − 5.9) ÷ 5.9 × 100 = +15.25%, so the model over-predicts the midspan deflection by more than the band allows and that row is flagged out of band. The same gap expressed as a percentage of the predicted value would be (6.8 − 5.9) ÷ 6.8 × 100 = +13.24% — still out of band, but a different number for the same physical disagreement, which is why the convention has to be stated.

The summary for this set: 4 of 5 rows in band; the worst row by absolute percentage is the midspan deflection at +15.25%; the mean absolute percentage error is 7.21%, from (5.34 + 3.41 + 15.25 + 4.00 + 8.06) ÷ 5; and the largest absolute deviation is the surface strain at 100 µε.

Read that last figure with care. The largest absolute deviation is expressed in the units of its own row, so it only compares like with like when every row shares a unit. Here the deviations are in MPa, Hz, mm, kN and µε, so 100 µε is not "bigger" than 14 MPa in any physical sense — it is simply the largest raw number. Treat the percentage column, not the raw difference, as the measure of how well the model did.

Scope and limitations

This checker is a computational aid. It performs arithmetic on the numbers you type in: a subtraction, a division and a comparison against the band you set. It does not validate a model, and it does not certify anything.

It is not a substitute for the applicable standard. Acceptance criteria for a correlation exercise come from the standard, code or customer specification that governs your component, from your own validation plan, or from the engineering judgement of the person signing the report — not from this page. The tolerance band here is a user-set threshold and nothing more; no band value shown or suggested on this page is a requirement of any standard.

It does not check that your data are comparable. It cannot see whether the gauge was at the right point, whether the load was the one you think it was, whether the mesh had converged, or whether the measured and predicted values describe the same location, direction and load step. Step 5 of the checklist above is the one that catches most bad correlations, and no calculator can do it for you.

It does not do statistics. The mean absolute percentage error here is a plain arithmetic mean of the absolute per-row percentages; it is not a confidence interval, a scatter measure, or a probability statement, and it should not be presented as one.

Frequently Asked Questions

Should the percentage difference be taken of the measured value or the predicted value?

Either is defensible, provided you pick one and state it. Percentage of the measured value treats the test as the reference and is the more common choice, which is why it is the default here. Percentage of the predicted value answers a different question — how large the error is relative to what the model claimed — and gives a slightly smaller figure whenever the model over-predicts. Changing the convention changes every percentage on the page, so record which one you used alongside the numbers.

What tolerance band should I use for FEA correlation?

There is no single correct number, and this tool does not supply one. The band should come from the applicable standard or your own validation plan, and it should reflect what the model is going to be used for: a band that is acceptable for a stiffness check may be far too loose for a fatigue assessment. Where nothing else dictates a figure, a tight band on linear static cases with well-characterised material and clean boundary conditions is realistic, and a looser one is honest where contact, plasticity or damping dominate — say which it is rather than quoting a percentage with no context.

Why does the tool report a row as not computable instead of a percentage?

Because the percentage would be undefined. If the measured value is zero and you are taking the percentage of the measured value, the calculation divides by zero; the honest answer is "not computable", with a message saying why, rather than an infinity or a blank that looks like zero error. The same applies if a value is missing or is not a number. Such a row is never counted as in band.