Decode an ATEX equipment marking

An ATEX equipment marking is a short code printed on the nameplate that states how, and where, a device may be used in a hazardous area. Read left to right, it names the equipment group, category and atmosphere, then the explosion protection concept, the gas or dust sub-group, the temperature limit and the equipment protection level (EPL).

Enter the marking as printed on the plate — for example II 2G Ex db IIC T4 Gb, Ex ia IIC T6 Ga, II 3D Ex tc IIIC T130°C Dc or Ex d IIB T4. Tokens use the standard upper- and lower-case form found on equipment plates. The list updates as you type.

Enter a marking above to see it decoded token by token.

How this decoder behaves. Each token is explained only when it is a marking element this tool recognises with certainty. Anything else is reported as not recognised rather than guessed — a token the decoder does not know, such as a non-standard letter, has no meaning invented for it.

How to use this decoder

  • Type or paste the marking exactly as printed, keeping the spacing and the upper/lower-case form (for example, Gb is an EPL, while db is a type of protection).
  • Read the results from left to right: they follow the order of the marking itself.
  • Use the reference tables below to check what a decoded token means in terms of where the equipment may be installed.
  • The tables are static HTML, so they remain readable even with JavaScript turned off. Only the live token-by-token decoder needs JavaScript.

ATEX marking chart: category, zone and EPL

The zone is a property of the place and is determined by the hazardous area classification study; the equipment category and EPL describe what the equipment is approved for. The two must match: the equipment fitted in a given zone must carry a category and EPL suited to that zone.

Zone, equipment category and EPL by hazard type
Hazard Zone Equipment category EPL
Gas, vapour or mist Zone 0 Category 1 Ga
Gas, vapour or mist Zone 1 Category 1 or 2 Ga or Gb
Gas, vapour or mist Zone 2 Category 1, 2 or 3 Ga, Gb or Gc
Combustible dust cloud Zone 20 Category 1 Da
Combustible dust cloud Zone 21 Category 1 or 2 Da or Db
Combustible dust cloud Zone 22 Category 1, 2 or 3 Da, Db or Dc

Mining equipment is handled separately, under equipment Group I. It is not assigned an ATEX zone; instead it carries one of two mining categories and their EPLs.

Mining (Group I) categories
Category EPL Level of protection
Category M1 Ma Very high protection — the equipment remains functional even while an explosive atmosphere is present.
Category M2 Mb High protection — the equipment is de-energised when an explosive atmosphere is detected.

Temperature classes T1 to T6

The temperature class sets the highest surface temperature the equipment is allowed to reach. It must sit below the ignition temperature of the substance that can be present, with a safety margin.

Temperature class and its maximum surface temperature
Class Maximum surface temperature Substances typically calling for it
T1 450 °C Hydrogen, methane, propane
T2 300 °C Ethylene, ethanol, butane
T3 200 °C Petrol, diesel, hexane
T4 135 °C Acetaldehyde, many common solvents
T5 100 °C Carbon disulphide (with gas group IIC)
T6 85 °C Substances with very low ignition temperatures

The class is a maximum surface temperature, not an ambient rating. T4 means the equipment's surfaces stay at or below 135 °C; it says nothing about the temperature of the surroundings. Dust equipment often states the surface temperature directly in degrees Celsius instead of a class — for example T130 °C — because the relevant limit is set by the dust cloud or dust layer ignition temperature rather than by a fixed class.

Gas groups and dust groups

The group says what the equipment may be used with. In the IEC 60079-0 group scheme, Group II covers gas atmospheres and is split into sub-groups IIA, IIB and IIC by how readily the gas ignites, while Group III covers dust and is split into IIIA, IIIB and IIIC by the nature of the dust.

One naming detail is worth knowing, because it appears on real nameplates. The ATEX Directive itself groups equipment as Group I (mining) and Group II (everything else), and marks dust within Group II by a D in the category — so an ATEX plate may read II 3D for dust equipment that the IEC group scheme calls Group III. Both describe the same device; the dust sub-groups IIIA, IIIB and IIIC are the same either way.

Gas and dust sub-groups with representative substances
Group Typical substances Notes
IIA Methane, propane, butane, most solvents The least readily ignited gas sub-group
IIB Ethylene, town gas, diethyl ether More readily ignited than IIA
IIC Hydrogen, acetylene, carbon disulphide The most readily ignited gas sub-group
IIIA Combustible flyings — textile fibres, wood shavings Suspended fibre and flyings hazards
IIIB Non-conductive dusts — grain, flour, wood, sugar Common organic and food-industry dusts
IIIC Conductive dusts — aluminium, magnesium and titanium powder, carbon black The most demanding dust sub-group

The hierarchy works one way only: equipment approved for a more demanding sub-group may be used where a less demanding one is required. IIC equipment is acceptable in an area classified IIA or IIB, and IIIC equipment is acceptable where IIIA or IIIB is required — never the reverse.

Types of protection at a glance

The letters that follow Ex identify the protection concept. A trailing letter a, b or c on the type of protection shows the protection level it reaches, which lines up with the equipment protection level.

Types of protection recognised by the decoder
Code Type of protection Standard
d Flameproof enclosure IEC 60079-1
e Increased safety IEC 60079-7
i Intrinsic safety (ia, ib, ic) IEC 60079-11
p Pressurisation / pressurised enclosure IEC 60079-2
m Encapsulation IEC 60079-18
o Oil immersion IEC 60079-6
q Powder filling IEC 60079-5
t Protection by enclosure, for dust (ta, tb, tc) IEC 60079-31
n Type of protection n (nA, nC, nR) IEC 60079-15
s Special protection — assessed and certified individually —

Worked examples

Each marking below is decoded step by step, in the order the tokens appear.

II 2G Ex db IIC T4 Gb
II
Equipment group II — surface-industry equipment for gas, vapour or mist atmospheres.
2G
Category 2, gas — high protection, suited to Zone 1 and permitted in Zone 2.
Ex
Marks explosion-protected equipment.
db
Flameproof enclosure (IEC 60079-1) at protection level b, associated with EPL Gb.
IIC
Gas sub-group IIC — suitable for IIA, IIB and IIC gases, including hydrogen.
T4
Temperature class T4 — maximum surface temperature 135 °C.
Gb
Equipment protection level Gb — confirms suitability for Zone 1 and Zone 2, but not Zone 0.
II 3D Ex tc IIIC T130°C Dc
II
Equipment group II — in the ATEX Directive's grouping, Group II covers all equipment other than mining; the D in the category that follows marks it for dust. The IEC group scheme refers to dust equipment as Group III.
3D
Category 3, dust — normal protection, suited to Zone 22 only.
Ex
Marks explosion-protected equipment.
tc
Protection by enclosure for dust (IEC 60079-31) at protection level c, associated with EPL Dc.
IIIC
Dust sub-group IIIC — conductive dusts such as aluminium or magnesium powder.
T130°C
Maximum surface temperature 130 °C, stated directly instead of a T-class.
Dc
Equipment protection level Dc — confirms suitability for Zone 22 only.
II 1G Ex ia IIC T6 Ga
II
Equipment group II — surface-industry equipment for gas, vapour or mist atmospheres.
1G
Category 1, gas — very high protection, suited to Zone 0 and permitted in Zone 1 and Zone 2.
Ex
Marks explosion-protected equipment.
ia
Intrinsic safety, level a (IEC 60079-11) — safe with two faults; associated with EPL Ga.
IIC
Gas sub-group IIC — suitable for IIA, IIB and IIC gases, including hydrogen and acetylene.
T6
Temperature class T6 — maximum surface temperature 85 °C.
Ga
Equipment protection level Ga — confirms suitability for Zone 0, and therefore also Zone 1 and Zone 2.

Two rules catch most practical mistakes when reading a marking. First, the category letters are not the same as the EPL letters — a category 2G device is rated Gb, but a category 3D device is rated Dc. Second, a marking states what the device is approved for, not what the area needs: the zone, the group and the temperature class still come from the classification study, not from the label.

Standards this decoder refers to

  • IEC 60079-0 (General requirements)
  • IEC 60079-10-1 (Gas classification)
  • IEC 60079-10-2 (Dust classification)
  • Directive 2014/34/EU (ATEX equipment)
  • Directive 99/92/EC (ATEX workplace)

Scope and limitations

This decoder is a reference aid only. It explains the marking tokens it recognises and nothing more; it does not certify, approve, assess or validate any equipment, and it makes no claim of conformity with any standard, directive or scheme.

A marking is never a substitute for the rest of the paperwork. Always confirm against the equipment documentation and nameplate, the certificate referenced on the plate, the hazardous area classification study carried out to IEC 60079-10-1 (gas) or IEC 60079-10-2 (dust), and the requirements of the applicable directive, ATEX 2014/34/EU for equipment and 99/92/EC for the workplace. If a token is reported here as not recognised, consult the equipment documentation rather than inferring a meaning from it.

Frequently Asked Questions

What does the marking II 2G Ex db IIC T4 Gb mean?

It is surface-industry equipment (Group II) for gas, in Category 2, so it is suited to Zone 1 and permitted in Zone 2. Ex db is a flameproof enclosure at protection level b, associated with EPL Gb. IIC means it is suitable for IIA, IIB and IIC gases, including hydrogen. T4 caps the surface temperature at 135 °C, and Gb restates the equipment protection level.

What is the difference between an equipment category and an EPL?

The category (1, 2 or 3, or M1 and M2 for mining) and the equipment protection level (Ga, Gb, Gc, Da, Db, Dc, Ma or Mb) both express how much protection a device provides, and the two map onto one another. The EPL was introduced to make the pairing between equipment and zone unambiguous: Ga suits Zone 0, Gb suits Zone 1 and Gc suits Zone 2, with the parallel Da, Db and Dc for dust. A marking usually shows both.

Is a temperature class the same as an ambient temperature rating?

No. A temperature class such as T4 limits the surface temperature the equipment may reach — 135 °C for T4 — so that it cannot ignite the surrounding atmosphere. It says nothing about the temperature of the surroundings. Any ambient range the equipment is rated for is a separate figure on the nameplate, not the temperature class.